Carbon Monoxide & Chimney Safety — Annapolis, MD

Carbon monoxide from fireplace and chimney systems is colorless, odorless, and immediately dangerous. The two most common chimney-related CO entry points are a blocked or damaged flue that backdrafts combustion gases into the living space, and a gas insert with an improperly sized or installed vent liner. Annapolis Chimney Pros connects you with CSIA-certified specialists who diagnose and correct CO entry pathways throughout Anne Arundel County.

(667) 493-2060 — CO Safety Assessment

Chimney-Related CO Causes in Annapolis Homes

If your CO alarm is sounding now: Turn off all appliances, open windows, and evacuate the building. Call 911 if anyone has symptoms (headache, dizziness, nausea). Re-enter only after the fire department gives the all-clear and identifies the source.
Most Common

Negative House Pressure Backdrafting

Modern energy-efficient homes in Anne Arundel County — particularly those in Arnold and Severna Park with improved insulation and air sealing — can develop negative pressure conditions where exhaust fans (kitchen, bath, HVAC) draw more air out than enters through infiltration. This negative pressure draws combustion gases down through the chimney flue rather than allowing them to draft upward. The fix is a dedicated combustion air supply to the firebox area.

Gas Systems

Improperly Sized Gas Vent

Gas fireplace inserts and log sets require vent liners sized to the appliance’s BTU output. An oversized liner — the original wood-burning flue — creates insufficient draft for the gas appliance, allowing CO-containing flue gases to spill back into the room. This is the most common gas insert installation defect found in Annapolis homes that converted from wood to gas without relining.

Blockage

Blocked Flue from Debris or Animals

Nesting material from squirrels, raccoons, or chimney swifts can partially or fully block the flue. A partial blockage creates a pressure imbalance that backdrafts during appliance operation. Chimney swifts (federally protected May through October) cannot be removed — an affected flue must remain unused for the nesting season.

Maryland CO Detector Requirements

Maryland law (Public Safety Article §9-220) requires CO detectors in every dwelling unit with a fuel-burning appliance or an attached garage. Anne Arundel County enforces this at the point of sale and during permit inspections. CO detectors must be installed within 15 feet of each bedroom. Battery-only detectors should be tested monthly; combination smoke/CO detectors typically require replacement every 7 years as the CO sensing element degrades.

Frequently Asked Questions — Chimney CO Safety Annapolis

How do I test whether my chimney is causing CO to enter the house?

A certified specialist uses a combustion gas analyzer to measure CO concentration at the fireplace opening and in the living space during appliance operation. This test, combined with draft measurement using a draft gauge, identifies whether CO is entering from the chimney and what the driving mechanism is. Standard home CO detectors are designed to alarm at chronic exposure levels, not at the low levels that indicate a marginal backdraft condition.

My gas fireplace has always worked fine. Why would it suddenly have a CO problem?

Several changes can create a CO problem in a previously safe installation: new weatherstripping or insulation that increased negative house pressure; a new kitchen range hood or bath exhaust that tips the pressure balance; a nest or debris accumulation in the vent liner; and deterioration of the appliance’s gas valve or burner assembly past its service life. Annual inspection catches each of these before they become a CO event.

Schedule a CO Safety Assessment

Annapolis Chimney Pros connects you with CSIA-certified CO safety specialists serving Annapolis, Eastport, Arnold, Severna Park, and all of Anne Arundel County. Combustion analysis included with every gas system inspection.